Medical Area Gas Alarm System For Hospital

Medical Area Gas Alarm System For Hospital

  • Oxygen Supply System Equipment

Inquire Now

The gas alarm box is used to monitor the pipeline pressure of the medical central air supply system and respond to the pressure change through electronic equipment. When the pressure is higher or lower than the set value, the system will automatically give an alarm by means of sound and light, so as to remind the management personnel to respond to the medical center air supply system.

Working principle of gas alarm box:

The gas alarm device adopts the electric contact pressure gauge to provide the switch signal, that is, the electric contact pressure gauge has two contacts of the upper limit and the lower limit of pressure, and the pressure value indicated by the contact represents the maximum and minimum allowable pressure of the gas pipeline respectively. The upper and lower limit contact values of the meter can be adjusted manually.

The electric contact pressure gauge is connected in series in the pressure pipeline. When the pipeline pressure is higher than the upper limit value, the pointer of the pressure gauge will contact with the upper limit contact, thus generating an electrical signal. Similarly, when the pipeline pressure is lower than the lower limit value, the pointer of the pressure gauge will contact with the lower limit contact, also generating an electrical signal, which we call the switch signal. The switch signal is connected to the circuit board of the gas alarm box to form a current pulse - when the high-voltage electric signal is connected, the gas alarm device will start the "overpressure" alarm, and at the same time, the overpressure LED indicator will flash; when the low-voltage electric signal is connected, the gas alarm device will start the "undervoltage" alarm, and at the same time, the undervoltage L The ED indicator also flashes. When the pipeline pressure returns to normal, the overpressure or undervoltage alarm will be automatically eliminated, and the system LED indicator will indicate the "normal" state.


Main features of gas alarm box:

1. The gas alarm box is installed on the nurse station of the ward building or the information panel of the operating room for the monitoring of the medical gas pressure;

2. Alarm switch signal is provided by electric contact pressure gauge or pressure switch;

3. The gas alarm box has a "test" function, which can test whether the alarm working state of each gas channel is normal;

4. When the system beeps due to the abnormal air pressure of the pipeline, press the "no sound" key to interrupt the sound alarm;

5. Under voltage, normal and over voltage monitoring states (corresponding to indicator lights of different colors) are set;

6. The gas alarm box is divided into three-way and seven way specifications, and the opening and closing control of a gas alarm function can be realized through the toggle switch;

7. The auxiliary computer can be connected through RS485 to realize the remote transmission of alarm signal;

8. It can be installed by wall embedding or hung on the wall;

9. It can only provide gas alarm panel or gas alarm box with integrated electric contact pressure gauge;

10. The gas alarm box is treated with aluminum alloy shell and surface frosting spray, which is beautiful.


Instructions for use of gas alarm box:

1. The gas alarm system is used to monitor the pressure state of the gas. When the pressure of the gas pipeline is higher or lower than the set value, the system will give an alarm prompt to remind the management personnel of timely maintenance.

2. The gas alarm system is triggered by the electric contact pressure gauge (or pressure switch) installed on the pipeline. When the pressure is lower than or higher than a certain value, the pointer of the electric pressure gauge will touch the corresponding contact to start the alarm device.

3. When an alarm occurs in a certain gas path, the buzzer set in the enclosure will give an alarm prompt, and the indicator light on the panel will flash correspondingly. When the gas pressure is higher than the set value, the red warning light above will flash; when the gas pressure is lower than a set value, the yellow indicator light below will flash; when the air pressure is normal, the green indicator light will light up.

4. When the alarm occurs, the operator can press the "Silence" button, at this time, the system stops beeping, but the alarm indicator still flashes until the pressure returns to normal. If the gas pressure does not return to the normal value within 20 minutes, the system will sound again to remind the operator to carry out maintenance.

5. The "test" button on the panel is used to detect whether all gas indication and alarm functions work normally.

6. The electric contact pressure gauge that triggers the alarm can set the maximum value and the minimum value according to the specific situation.

7. The gas alarm system can be set with 7 gas alarm signals at most, and users can turn off some gas signals by themselves. The alarm device can be equipped with auxiliary alarm device, and the main alarm device and auxiliary alarm device can be connected through 485 signal.

 

Hot Products

Medical lamp, Medical pendant, Bed head unit, Medical endoscopic trolley, Gas outlet Manufacture & Supplier from China

Shanghai Zhenghua Medical Equipment Wechat